VA Membrane Solutions
For Sale
Own It: U.S. Built VA/EA SYSTEMS
Custom-manufactured in Napa, CA, our systems range from standard to fully tailored designs—all with U.S.-sourced or stocked parts and rapid support.
Configurations:
- Semi-Auto (No CIP) – Standalone columns
- Semi-Auto + CIP – Standalone Columns
- PLC- Semi -Automated + CIP – Integrated Columns
Equipment Sizing: Our equipment is sized to produce 30% reduction of VA/EA at the ‘Reduction Rate.'
Standard Equipment
Standard equipment on 8” VA Membrane systems – Suffix VSA1
- 316ss Piping and fittings with an inlet sight glass
- Alfa Laval butterfly valves, VNE ball valves
- Y pre-filter – 180 microns (2&4 Vessel) Bag pre-filter – 150 microns (VA8-6-300VSA1, VA8-12-300HSA1)
- Hydracel high pressure pump – 5hp (2 & 4 Vessel) 10 HP (VA8-6-150VSA1) 15HP (VA8-12-300HSA1)
- VPM Membrane elements standard – BPM/STA optional
- 2 x Pressure sensors with digital display
- Pressure shut off on high permeate and high concentrate pressures
- Magnetic flow meter on permeate line
- SS Electrical panel including push-button start and batch permeate control
- Variable speed control drive for pump
Standard Equipment on 8” VA Membrane systems – Suffix VSA1-CIP
- 316ss Piping and fittings with inlet and permeate sight glasses
- Alfa Laval butterfly valves, VNE ball valves
- Y pre-filter – 180 microns (2&4 Vessel) #1 Bag style pre-filter – 150 microns (VAF8-6-300VSA1-CIP)
- CIP tank and pipework/valves for clean in place
- Grundfos feed/CIP pump
- Hydracel high pressure pump – 5hp (2 & 4 Vessel) 10 HP (VA8-6-150VSA1-CIP)
- VPM Membrane elements standard – BPM/STA optional
- 2 x Pressure sensors with digital display
- Pressure shut off on high permeate and high concentrate pressures
- Magnetic flow meter on permeate line
- Electrical panel including push button and batch permeate control
- Variable speed control drive for both pumps
Standard Equipment on 8” Mobile Style Membrane system
- 316ss Piping and fittings
- Alfa Laval butterfly valves, VNE ball valves
- #2 Bag style pre-filter – 150 microns
- CIP tank and pipework/valves for clean in place
- Grundfos feed/CIP pump
- Hydracel high pressure pump – 15 HP
- 6 and 6 parallel membrane arrangement, can be run on just 6 to limit losses or to mix VPM/BPM/STA membranes.
- VPM Membrane elements standard – BPM/STA optional
- 6 x Pressure sensors digital display - IFM
- Pressure shut off on 6 measured values and differential pressure
- Magnetic flow meter on feed and permeate - IFM
- Automated electrical back pressure control valve
- 4 x 100 Liter resin columns mounted inside the frame
- Regen manifold
- SS Electrical panel including 7” HMI and remote accessibility with logging and batch e-mail feature
| 8" Membrane Systems for VA - SA1 Semi-auto Panel (no CIP or Resin Columns) |
| Model Number | Configuration | Reduction Rate |
| VA8-2-50VSA1-X | 2 x 8” Vertical Membrane System | 125 gph |
| VA8-4-100VSA1-X | 4 x 8” Vertical Membrane System | 250 gph |
| VA8-6-150VSA1-X | 6 x 8” Vertical Membrane System | 375 gph |
| VA8-12-300HSA1-X* | 12 x 8” Horizontal, Parallel Membrane System | 750 gph |
| 8" Membrane Systems including CIP system for VA – SA1 Semi-auto Panel (No resin columns) |
| Model Number | Configuration | Reduction Rate |
| VA8-2-100VSA1-CIP-X | 2 x 8” Vertical Membrane System | 125 gph |
| VA8-4-200VSA1-CIP-X | 4 x 8” Vertical Membrane System | 250 gph |
| VA8-6-300VSA1-CIP-X | 6 x 8” Vertical Membrane System | 375 gph |
| 8” Membrane Systems including CIP and separate VA/pHC Resin column rack – SA1 Semi-Auto |
| Model Number | Configuration | Reduction Rate |
| VA8-2-100VSA1-CIP-X+RK | 2 x 8” Vertical with 60 Liter resin column rack | 125 gph |
| VA8-4-200VSA1-CIP-X+RK | 4 x 8” Vertical with 60 Liter resin column rack | 250 gph |
| VA8-6-300VSA1-CIP-X+RK | 6 x 8” Vertical with 60 Liter resin column rack | 375 gph |
| 8” Mobile Style VA Reduction equipment with onboard 4 x 100 liter resin columns (PLC Controlled) |
| Model Number | Configuration | Reduction Rate |
| VA8-6/6-300HSA2-CIP With 4 x 100l VA Columns |
12 x 8” Horizontal Parallel Membrane System w/ Integrated VA Columns | 750 gph |
| Optional – Resin Columns and resin column racks |
| VA60-M | Manual 60 Liter VA resin column |
| pHC60-M | Manual 60 Liter pHC resin column |
| Regen pump box | For VA Resin regen |
| Venturi | For pHC column regen |
| VAPHC-60-DS | Skid mounted DS VA & DS pHC rack – 60 Liter resin capacity (4 columns) |
| VAPHC-100-DS | Skid mounted DS VA & DS pHC rack – 100 liter resin capacity (4 columns) |
| Smoke Reduction Columns |
| PAC-60 | 14” Diameter 60l Column with fittings (excl media) Requires 2 ft3 media |
| PAC-60 Media | PAC media |
| ARC-60 Column | 14” Diameter 60l Column with 2ft3 media |
| PAC-20 Column | 8” Diameter 20l Column with fittings (excl media) Requires 0.75 ft3 media |
| ARC-20 Column | 8” Diameter 20l column with 0.75 ft3 ARC media |
| PAC60/ARC100 | Skid mounted, 2x PAC60 and 2x ARC100 w/ media, including complete manifold and venturi |
| Replacement Membranes |
| 4” Membranes | All types including VPM, BPM, STA, STB, STC, STE and Crossflow |
| 8” Membranes | All types, including RO, VPM, BPM, STA, STB, STC, STE and Crossflow |
| NOTE: Equipment is designed for purposes of VA reduction or taint removal and can operate at up to 600 psi. All systems include high pressure shut off, low flow shutoff and auto batch flow shut-off (SA1). All flow rates shown are with standard VPM elements. 4 membranes can be ordered as 2_4 or 2/2, 6 membranes can be ordered as 3_6 or 3/3. Can be used for UF purposes with a membrane change, but with less crossflow than a true UF. VA8-2s, upgradeable in the field to VA8-4 later |